Serial number
Administrator password
Data type identifier
Object Identifier/ Installation addresss
[EtYP] - Operation mode of electronic cassette
[ EAu ] - Sound signal of sign selected from the keyboard
[ ton ] - Multitone signalling of sign selected from the keyboard
[ dJ ] - dJ
[ EUC ] - Supply of camera and illumination
[ 3C ] - Switching on three-position display
[ tOc ] - Waiting time for picking up the receiver in seconds
[ tro ] - Time of conversation
[ t1d ] - Time of signal generation
[ tPA ] - Pause time
[ trY ] - Time of electrocatch operation in second
[ FrY ] -Frequency of electro-catch supply voltage in Hz
[ APo ] - Acoustic confirming opening the electrocatch
[ CEn ] - Switching on coded lock service
[ idE ] - Switching on/off electronic keys
[ idA ] - Registration of electronic keys by users
[ NbL ] - Mode with building numbering
[ LdP ] - Directing of not serviced numbers
[ NbP ] - Block number for directing of not serviced numbers
Numbering modes
Code of coded lock
Supply of camera and illumination
Electro-catch
Calling options
Electronic keys
A unique serial number of the processor, according to which computes an array of electronics in the cassette lock codes.
It is printed on a sticker on the processor.
You can edit it, which is useful for example in the case of a edit operation mode of electronic cassette from U on H.
It can take values from 0000 to 9999.
If in the number is the digit 0, then it must also be entered.
Parameter changes can be made insection [ System parameters – grouped by functionality ].
Default administrator password is the serial number printed on a sticker on the processor.
You can edit it in the ISD-02 program. It can take values from 0000 to 9999. If in the the number is the digit 0, then it must also be entered.
NOTE!
If you forget password, then without interface ISD-02 and ISD-02 program it is impossible to retrieve it and it will be necessary
to restore the default settings electronic cassette, which involves the loss of all entered settings.
Administrator password can be changed in section [ System parameters – grouped by functionality ].
Since version 6.7 software of electronic cassette in EEPROM memory is saved a special identifier that
identifies system type, software version and operation mode of electronic cassette ( U or H ).
Data type identifier allow self identification of electronic cassette type during receiving data from the EEPROM memory to ISD-02 program.
NOTE!
During each process of receiving data from the EEPROM memory of it should be noted that the program correctly determined the electronic cassette type.
In the case of an erroneous reading, set the parameter [Data type identifier] yourself.
addresss or name of the object, in which the electronic cassette is installed. Parameter help more easily identify the data and the files.
Name can contain 20 characters.
During saving data into files it will be default name of file -e.g.
Parameter defining operation mode of electronic cassette:
NOTE!
The parameter is not editable! To change the mode cassette electronics - see Menu/Instruction section Changing the Operation mode of electronic cassette.
If this parameter is [ On ], then selection of any sign from the keyboard may be signalized with short acoustic signals heard on the speaker panel.
If this parameter is [ Off ], then selection of a key may be signalled with the same sound (one tone signalling) or (if [ ton ]=[ On ]) for every key sound of different pitch may be attributed (multitone signalling). The use of this function requires fulfilling the following condition [ EAu ]=1 and [ ton ]=1.
Duration of acoustic signal which signals selection of any sign from the
keyboard is as long as time of keystroke but no longer then 1 second.
The use of this function requires fulfilling the following condition [ EAu ] and [ ton ].
Parameter was add in version 6.6 software of electronic cassette.
Supply of camera and illumination
Time of electrocatch operation in second [s].
Electro-catch supplied with alternating voltage from a transformer
makes a characteristic sound (humming) which is often associated
with opening of door. This parameter makes it possible to simulate the operation of an electro-catch.
Entering value [ 0 ] makes that an electro-catch will operate without making any sound.
NOTE:
Electromagnetic lock should be supplied by voltage 12 V DC/1A.[ FrY] = [ 0 ]!
Setting parameter [ CEn ] to [ Off ] value makes that function of coded lock will be switched off for all users regardless of setting for the individual apartments.
If parameter is set to [On] is possible switched off that function for indywidual users in section [ Lock codes / Locks Options ]
setting parameter Lock code to "[-] - Off".
In section [ System parameters – grouped by functionality → Code lock parameters] or [ Parameters – order according to the system → Bit Parameters ] default value parameter [ idE ] is [ On ] - function of coded lock is switched on for all users.
In a system is possible registration of electronic keys by users. Setting parameter [ idA ] value to [ On ] in section [ System parameters – grouped by functionality → Code lock parameters] or [ Parameters – order according to the system → Bit Parameters ] permits users to register new electronic keys from user's menu.
Switches on the mode with the building numbering.
This numbering mode can be used only in entry phone system with entrance hierarchy (main entrance and subordinate entrances).
This numbering mode allows repeating apartment numbers in different buildings.
In electronic cassette for subordinate entrance set parameter [ nbL ] (block number) to value higher then zero.
The operation should be repeated for other staircases (buildings). Values [nbL] can be repeated in subordinate systems provided that these systems operate
with other logical numbers of uniphones.
In order to get connection with an apartment from an external panel at the main entrance one should first of all select building number and then apartment number.
The value parameter indicates the logic number to which all numbers which are not serviced will be directed.
All numbers which are not serviced by entry phone CD-2502, will be directed to uniphone number given as LdP value, connected to
electronic cassette which parameter nbL is the same as parameter NbP.
If local number is in the range of serviced number ( parameters [ LLo ] and
[ LHi ]) and it is [Off] (parameter [ Mode ]in section [ Lock codes / Locks Options ] is set to "[-] - Off")
in subordinate entrance (U), than dial the uniphone which is switched off will cause the call forward.
Digital entry phone as a standard can operate numbers within a range 1...255 (Normal mode), however, very often it is necessary to operate higher numbers or numbers of considerably wider range. This is possible owing to different numbering modes:
Number of uniphone (programmed by jumpers) within a range 1...255.
Number under which a uniphone rings after having selected the number from the keyboard - within a range 1...9998.
In normal mode physical number of uniphone (programmed by jumpers) corresponds to logical number (selected from the keyboard of talking cassette). This is a default mode of operation of entry phone exchange.
This numbering mode can be used only in entry phone system with entrance hierarchy.
This numbering mode allows repeating apartment numbers in different buildings.
In order to get connection with an apartment from an external panel at the main entrance one should first of all select building number and then apartment number.
In electronic cassette for subordinate entrance set parameter [ nbL ] (block number) to value higher then zero and in electronic cassette
for main entrance parameter [ NbL ] to value [ On ].
Values [ nbL ] can be repeated in subordinate systems provided that these systems operate with other logical numbers of uniphones.
All numbers which are not serviced by entry phone CD-2502, will be directed to uniphone number
given as [ LdP ] value, connected to electronic cassette which parameter [ nbL ]
is the same as parameter [ NbP ].
*Since version 6.7 software of electronic cassette - If local number is in the range of serviced numbers and is turn off,
than is automatically treated as unserviced number (parameter [ Mode ] in section
[ Lock codes / Locks Options] in subordinate entrance
Supply of camera and illumination of camera in external panel is turn on only during the conversation. Users can not monitor picture from camera.This is default mode - parameter [ EUc ] in section [ System parameters – grouped by functionality → Operation parameters of the system ] or [ Parameters – order according to the system → Bit Parameters ] has value [ OFF ]. If users want to monitor picture from camera continuously [ EUc ] should be set to [On].
Supply of camera and illumination of camera in external panel is continuously.
If users want to monitor picture from camera also in the night, than the illumination of camera should be turn on continuously.
In section [ System parameters – grouped by functionality → Operation parameters of the system ] or
[ Parameters – order according to the system → Bit Parameters ] parameter [ EUc ] should be set to [ ON ].
NOTE: Even if illumination of camera is turn on continuously, it will be turn off automatically by photoelement in case of good enough external illumination.
Time of electrocatch operation [ trY ] can be set in section [ System parameters – grouped by functionality → Door opening parameters ] or [ Parameters – order according to the system → Numerical parameters ].
Entering value [ 0 ] to parameter [ FrY ] in section
[ System parameters – grouped by functionality → Door opening parameters ] or
[ Parameters – order according to the system → Numerical parameters ]
makes that an electro-catch will operate without making any sound.
Entering value diffrent then [ 0 ] makes a characteristic sound (humming) which is often associated with opening of door.
Since version 6.7 software of electronic cassette - first 250ms always DC.
NOTE:
Electromagnetic lock should be supplied by voltage 12 V DC/1A.[ FrY] = [ 0 ]!
Calling signal consists of several parts:
Parameters: number of bells, calling ton, calling volume can be set for indywidual users. Signal frequency, time of individual tone generation, pause time, waiting time for picking up the receiver are global parameters for all users conected to this electronic cassette.
Successive tons of different frequency [ F0 ] (1 kHz), [ F1 ] and [ F2 ] form single signal [ t1d ].
Time of signal generation [*10ms]
Time of signal generation consists of signals [ t1t ] of different frequency.
Pause time *10[ms]
Pause after signal [ t1d ]
Waiting time for picking up the receiver in seconds
Entry phone CD-3100 can be equipped with electronic key reader. There are three kinds of keys in entry phone:
Keys should be registered at both the main and subordinate entrance. At the main entrance keys attributed to apartment cannot be registered. Entry phone users can register their own electronic keys. This possibility can be switched on globally by setting parameter [ idA] to value [On].
ISD-02 interface allow registration electronic keys in electronic cassette, addition of keys with attributing to apartment, addition on the selected item in memory,
and copying keys ( all or whole section) from one electronic cassette to other, or saving settings in file.
Using program ISD-02 it is possible to write and read data to the table to / from a file with the extension *.tm, that is
so after programmed keys in one electronic cassette it is easily to copy it to another located in the system (for example, to copy from subordinate entrance cassette tapes to main entrance cassette).
To save the table select in section [ Electronic keys ] the area you want to copy and press the right mouse button and choose [ Save to file ],
and give it a name.
To load data into an table, press the right mouse button in the line of the table and choose [ Import from file ].
NOTE:The data that we import from the file will be inserted into the cell line which pointed out. Data in the table will be replaced data imported from the file.
Example:
In file is 12 keys, if we paste them from position 100 then data from positions 100-111 will be deleted and replaced by new.
Saved file can be edited. To make change it should be opened in any program to text edition (eg. notepad) made data changes, and finally file must be saved
Besides addition keys by installing specialist it is possible addition keys by users after setting parameter [ idA] to [On].
The program allows addition:
If you want to add one electronic key, then in section [ Electronic keys ] choose [ Add ] and apply key to the reader ISD. The serial number of electronic key will bereading and show in the box [Serial Number]. This key will be add to first free position. If this key was earlier registrated it will not be add – line with this particular key will be highlighted.
If you want to add several keys at once, then choose [ Add ] and apply all keys successively to the reader ISD. They will be successively added to the first free position.
If you want to add one electronic key tospecific position, then in section [ Electronic keys ]:
If you want to verify that the key is already registered in the system - in section [ Electronic keys ] choose [ Verify key ] and apply key to the reader ISD. If this key was earlier registrated line with this particular key will be highlighted.
There is possibility of addition one key to several electronic cassette (eg. several subordinate entrances and one main entrance, or only to subordinate entrances). For postmen, administration etc. aside an area designated numbers 1000-1019, which can select and save the file, and during programming other electronic cassette import selected area table to area designed for special keys used by postmen, administration etc. in section [ Electronic keys ].
Deleting the key from memory will take place after marking line with key and pressing on the keyboard 'Delete'. Deleting all keys from memory will take place after marking any cell in the table and pressing at the same time 'ctrl' and 'a'on the keyboard and next 'Delete'.